Model |
BD210801 |
|
Insulation Test Voltage Ranges |
500 V d.c. |
|
Insulation Resistance Range |
0 to 200 MW |
|
Resistance Range |
0 to 1 MW |
|
Continuity Ranges |
0 to 200 W |
|
|
0 to 2 W |
|
Voltage Range |
— |
|
Terminal Voltage Insulation Resistance Range |
<600 V >500V at 0.5 MΩ) |
|
Terminal Voltage Resistance Range |
53 V |
|
Terminal Voltage Continuity Ranges |
0.76 V |
|
|
4.7 V |
|
Terminal Current Insulation Resistance Range |
1.6 mA |
|
Terminal Current Resistance Range |
325 μA |
|
Terminal Current Continuity Ranges |
12.3 mA |
|
|
210 mA |
|
Accuracy (at 20°C) |
[2.5% of scale length on all ranges (i.e., ±1.9 mm (0.075 in.) on insulation resistance range] |
|
Movement |
250 μA full scale deflection
|
250 μA full scale deflection |
|
Voltmeter Input Impedance |
330 kΩ
|
— |
|
Power Supply |
Single 9 volt battery, IEC 6 LR61 type |
|
Current Consumption |
110 mA max. on insulation range, 40 mA max. on resistance range, 220 mA max. on 2Ω range |
|
Battery Life |
More than 1800 5 second operations on 2Ω range |
|
Safety |
The instruments will, in general, meet the requirements of the IEC 1010-1 (1990) safety specification. |
|
Safety Class II, Flash test to 4 kV peak impulse. Phase-to-Phase voltages not exceeding 500V a.c. |
|
Weight/Dimensions |